Tesla alert · Onboard Charger High

CHG_f017Charger Bus Voltage High

CHG_f017_hwIntermediateBus

The onboard charger has detected that the voltage between itself and the high-voltage battery has exceeded safe levels. This is a hardware-level safety check to prevent damage to the battery or charging electronics.

High-voltage safety: Tesla battery, drive unit, and charging components carry lethal voltage. Never open, unplug, or probe orange cables or high-voltage parts — leave inspection to Tesla Service or a certified EV technician.

Is it safe to drive?

Usually OK to drive

You can drive, but you will likely be unable to charge until this is resolved.

Who should fix it

High-voltage professional only

This involves high-voltage parts. Only Tesla Service or a certified EV technician should inspect or repair it.

How often owners see it

Common

Shown on the touchscreen or in the Tesla app. Standard OBD-II scanners don't read Tesla alerts.

Likely causes

  • Onboard Charger Failure

    Internal component failure in the AC-to-DC conversion path.

    high
  • External Power Spike

    A surge from the power grid during a charging session.

    low

What to do next

  1. 1Unplug the vehicle immediately.
  2. 2Try a scroll-wheel reset to see if the hardware check clears.
  3. 3Attempt to charge at a different location to rule out grid issues.
  4. 4Contact Tesla Service as this typically involves high-voltage hardware replacement.

Related Onboard Charger alerts

Common questions about CHG_f017

Will this alert stop me from driving?

No, it primarily affects the charging system, but you will be stranded once your current battery charge runs out.

What is an 'Intermediate Bus'?

It is an internal electrical pathway that moves power between the charger and the main battery pack.

Ask Wrenchify about CHG_f017 on your Tesla

Add your model and year for guidance on symptoms and next steps — free plan included.