Battery Charging System Positive Contactor C Stuck Closed
High severity
What it means
The positive contactor C of the battery charging system reports a stuck closed condition. HV charging path cannot be commanded reliably.
Is it safe to drive?
No — stop driving
This code can put the vehicle into limp or reduced-power mode. Avoid extended driving and have the vehicle diagnosed promptly.
Most likely causes
Contactor contacts welded closed
highOne of the most commonly reported causes for this code — check this first.
Output driver stuck on
mediumA plausible cause — test and verify before replacing parts.
Carbon or debris buildup preventing free movement
lowLess common, but worth ruling out after the more likely causes.